Reason for tripping of distribution box:
1. Check if the air switch is damaged.
2. Check if the air switch wiring is correct. Incorrect and rewire.
3. Check the insulation of the circuit on the load side of the air switch. If there is a short circuit and grounding, it is necessary to eliminate the problem before closing it normally.
If it trips as soon as power is transmitted, it indicates that the circuit is short circuited to ground.
A netizen asked if the reason for the main switch always jumping at home could not be found. According to his description, it should be that the zero line of a certain sub circuit is grounded.
Based on the description of netizens and photos of his distribution box, it was found that his circuit breaker was a 1P micro circuit breaker. The breaker only disconnected the front, and the neutral line was still connected. Regardless of which circuit had no faults, electricity would pass through the faulty circuit's neutral line and go underground. Therefore, the main circuit breaker leakage circuit breaker will still trip. When checking, disconnect one output line slightly each time and remove the zero wire of this circuit, then check in sequence to see which branch has the problem.
If the problem lies in the neutral line of No. 3, if you disconnect the neutral line of No. 3, other 1, 2, and 4 will still pass through the ground of the neutral line of No. 3. Only by removing the neutral line 3 and ensuring that the main switch does not jump can the fault be determined to be in the neutral line 3.
If the main switch of the home distribution box is to choose a branch with leakage, it is recommended to choose a 2P micro break, as shown in the figure below. This type of maintenance is more convenient. In case there is a leakage problem that breaks the faulty branch, the other branches can still use electricity normally and wait for the master to repair it.
After the introduction by the editor above, we believe that we have a certain understanding of the air switch of the distribution box and have grasped some relevant knowledge
Here, the editor recommends that when selecting distribution boxes, we choose some big brand distribution box brands, as large brand distribution boxes are relatively reliable.
Article source: Jiangmen distribution box http://www.gdsandingdianqi.com/
02-28
What are the safety technical requirements for Jiangmen substation cabinets
Assembling switchgear, measuring instruments, protective appliances, and auxiliary equipment into enclosed or semi enclosed boxes or screens forms a distribution box. What are the safety technical req
02-28
Installation environment requirements for Jiangmen substation cabinets
In the process of our practical installation, if the orientation of the distribution box is not very perfect or does not meet the requirements of the practical site, the installation personnel should
02-28
Wiring principles of Jiangmen distribution box
We cannot do without electricity. We use electricity almost every day, and electricity has become an indispensable part of our daily lives. Today, we will introduce the wiring guidelines for distribut
02-28
How to deal with the tripping of Jiangmen distribution box
Reason for tripping of distribution box:1. Check if the air switch is damaged.2. Check if the air switch wiring is correct. Incorrect and rewire.3. Check the insulation of the circuit on the load side